ookura_13-54_catalog_map


>> P.312

Mitutoyoreservestherighttochangeanyorallaspectsofanyproductspecification,includingprices,designsandservicecontent,withoutnotice.DigimaticIndicatorsABSOLUTEDigimaticIndicatorID-CSERIES543—Peak-ValueHoldType•ThePeakHold-TypeDigimaticIndicator.Go/No-gojudgmentisperformedbysettingtheupperandlowertolerancesformax.,min.andrunoutvalues.*1•Fivebuttons,statusicons,andclearbuttonindicationsalloweasyoperationandvariousfunctions.•Widedisplayandnewanalogbargrapharestandardonallmodels.•TheABS(ABSOLUTE)scalerestoresthelastoriginposition*2automaticallywhentheindicatoristurnedon,andrealizeshighreliabilitybyeliminatingover-speederrors.•Equippedwithadataoutputportthatenablesincorporationintomeasurementnetworkingandstatisticalprocesscontrolsystems.(Refertopage09-3)•Byusingtheparametersetupkit(optional)andthededicatedsoftware,thefunctionsandtheparameterscanbeconguredusingacomputer.*1Tolerancejudgmentresultscannotbeoutput.*2Referto“Precautionsforuse”onpage07-2.543-300-10/543-300B-10SPECIFICATIONSMetricISO/JISTypeCodeNo.Range(mm)Resolution(mm)Maximumpermissibleerror(MPE)*1(mm)PartialmeasuringrangeMPEPTotalmeasuringrangeMPEEHysteresisMPEHRepeatabilityMPERMaximumpermissiblelimit(MPL)Measuringforce(N)543-300-10543-300B-10(atback)12.70.001/0.01(selectable)Inch/MetricISO/JISType0.0030.0030.0030.0021.5orlessBatterylife(normaluse)*2Mass(g)Approx.1year180170Maximumpermissibleerror(MPE)*1(mm)PartialmeasuringrangeMPEPTotalmeasuringrangeMPEEHysteresisMPEHRepeatabilityMPERMaximumpermissiblelimit(MPL)Measuringforce(N)Batterylife(normaluse)*2Mass(g)CodeNo.RangeResolution543-301-10543-301B-10(atback)0.5in/12.7mm0.00005/0.0001/0.0005in,0.001/0.01mm(selectable)Approx.1year180170Batterylife(normaluse)*2Mass(g)Approx.1year1951700.0030.0030.0030.0021.5orlessInch/MetricASME/ANSI/AGDtypeCodeNo.RangeResolution543-302-10543-302B-10(atback)0.5in/12.7mm0.00005/0.0001/0.0005in,0.001/0.01mm(selectable)Maximumpermissibleerror(MPE)*1(in)Overall*3HysteresisRepeatabilityMaximumpermissiblelimit(MPL)Measuringforce(N)±0.000100.000100.000101.5orless•Powersource:CR2032battery(1pc.),includedasstandard(foroperationalchecks)*1Thesevaluesapplytonormalmeasurementsat20°C.*2Appliesonlyifnotconnectedtoadataprocessor.Batterylifedependsonuseoftheindicator.Usetheabovevalueasaguideonly.*3Overallmagnicationandlinearity07-13Functions•Peakdetection(MAX/MIN)•Runout(MAX-MIN)HoldNote:Peakdetection1)Samplingrate:50readings/s2)Capturingspeed:50µm/s(max.)•Zeroset(INCsystem)•Presetfunction(ABSsystem)•Measuringdirectionswitching•Tolerancejudgment(3pairsofABS,INCmemoryfunction)•Resolutionselection•Simplecalculationf(x)=Ax•Analogbarresolutionselection•Keylock•in/mmconversion(inch/mmtype)•Displayhold(whennoexternaldeviceisconnected)•Dataoutput•ExternalPCsettinginput•Displayrotation(330°)•Lowbatteryvoltagealarmdisplay•ErroralarmdisplayOptionalAccessoriesCodeNo.TypeDescription264-020—90533890540906AFM380F02AZD790F02AZE140FFFFFFUSBInputToolSeriesUSBKeyboardSignalConversionTypeIT-020UConnectioncable(1m)Connectioncable(2m)USBInputToolDirect(2m)ConnectioncableforU-WAVE-T(160mm)ConnectioncableforU-WAVE-TForfootswitch264-622264-623IP67U-WAVE-TMBuzzerU-WAVE-TM02AZD810D—U-WAVE-R264-626264-627IP67U-WAVE-TMBBuzzerU-WAVE-TMB02AZF670—U-WAVE-TM/TMBmountingbracket:forDigimaticIndicators•Lifting21EZA198LiftingleverLiftingknob21EZA105•Parametersetupkit:21EZA313Note:Parametersettingsoftware(canbedownloadedforfreefromtheMitutoyowebsite)isalsorequired.ParametersetupkitParametersettingsoftware•ContactpointsforMitutoyo’sDigimaticindicators(optional)Refertopages07-63to07-68fordetails.•InterchangeablebacksforSERIES2models(optional)Refertopage07-69fordetails.•Measuringstands(optional)Refertopages07-97to07-103fordetails.


<< | < | > | >>